New features:- Length ratio calculation.
- Ellipsoid / bullet volume calculation.
Improvements and bug fixes:- Added support for certain DICOM files not fully compliant with the standard.
- Added support for some uncommon DICOM images with JPEG 2000 encoding.
Improvements and bug fixes:- Image position, zoom, rotation and flip is restored when switching series.
- Added support for certain DICOM images not fully compliant with the standard.
- Added support for certain US images encoded with JPEG YBR.
- Improved distraction free mode.
- Other small improvements and bug fixes.
New features:- Distraction free mode (Alt + Shift + Enter).
Improvements and bug fixes:- Added support for certain DICOM images not fully compliant with the standard.
- Added support for DICOM images with pixel data stored in 32-bit cells.
- Improved naming of folders when exporting all series (added patient ID, changed date formatting).
- Fixed display for certain US images with JPEG YBR compression.
- Fixed rare issues with distorted 3D reconstructions and measurements for certain DICOM files not fully compliant with the standard.
New features:- Distraction free mode (Alt + Shift + Enter).
Improvements and bug fixes:- Added support for certain DICOM images not fully compliant with the standard.
- Added support for DICOM images with pixel data stored in 32-bit cells.
- Improved naming of folders when exporting all series (added patient ID, changed date formatting).
- Fixed display for certain US images with JPEG YBR compression.
Improvements and bug fixes:- Added option to open quickly a series via context menu.
- Added option to draw horizontal or vertical segments when using angle or Cobb angle tools while holding Shift.
- Added option to hide DICOM overlays.
- Added option to set custom directions for WL/WW adjustments in options.xml.
- For DICOM files with imager pixel spacing defined (e.g., CR/DX/XA), magnification factor is used for length measurements whenever possible. The length measurement's background color will turn blue if a radiographic magnification factor is applied (whereas for measurements at the detector plane, the color is purple).
- Fixed issues with not fully DICOM compliant tomosynthesis images (Hologic).
- Fixed rare issue (white lines) with images having lossless JPEG compression.
- Fixed WW/WL setting for certain images with VOI LUT defined.
- Fixed issues with certain PALETTE COLOR images compressed with JPEG2000 lossless codec.
- Removed support for Windows XP and Vista systems.
New features:- Set custom window (WL/WW or Min/Max) with the option to use SUVbw units for PET images.
Improvements and bug fixes:- Improved responsiveness during WW/WL adjustment for high resolution images (mammography, etc.)
- Improved performance when loading large number of series into viewer.
- Improved "Split series" function for multi-sequence MR series.
- Fixed issue when after loading a series, an image other than the first one was shown.
- Other performance and stability improvements.
New features:- Set custom window (WL/WW or Min/Max) with the option to use SUVbw units for PET images.
Improvements and bug fixes:- Improved responsiveness during WW/WL adjustment for high resolution images (mammography, etc.)
- Improved performance when loading large number of series into viewer.
- Fixed issue when after loading a series, an image other than the first one was shown.
- Other performance and stability improvements.
New features:- Option to read password-protected, AES-256 encrypted DICOM data from the CD/DVD/USB Flash.
- Closed polygon tool - area, perimeter.
- Open polygon tool - length.
- Arrow tool.
Improvements and bug fixes:- SUVbw measurements (no fusion required).
- Added option to show destination folder in Explorer after export.
- Added info about the displayed image series to the title bar text.
- Added Ctrl+F1 shortcut to show the About box.
- Improved rendering of structured reporting (SR) documents in the viewport - page breaks for longer content, XML/HTML tag stripping.
- Custom character encoding can be set for SR documents in options.xml.
- Changed version numbering scheme (YYYY.X.Z - YYYY: year of the public release, X: feature release number, Z: bugfix release number).
- Added support for TIC generation for MR studies with multi-frame DICOM files.
- Updated DICOM dictionary to 2020a.
- New mouse button indicators (back and forward buttons added).
- ESC deletes the unfinished measurement.
New features:- Image filters (sharpen, smooth, edge...).
Improvements and bug fixes:- Added support for extended mouse buttons (the forward button for ROIs / the back button for panning).
- Added option to disable horizontal mouse wheel (via options.xml).
- Added option to export movies in MP4 format from 2D viewer.
- Added support for certain not fully conformant JPEG compressed DICOM files.
- Fixed several bugs causing crashes and hangs.
- Fixed issue with opening multiple viewer windows when in full screen mode.
New features:- Image filters (sharpen, smooth, edge...).
Improvements and bug fixes:- Added support for extended mouse buttons (the forward button for ROIs / the back button for panning).
- Added option to disable horizontal mouse wheel (via options.xml).
- Added option to export movies in MP4 format from 2D viewer.
- Added support for certain not fully conformant JPEG compressed DICOM files.
- Fixed several bugs causing crashes and hangs.
Improvements and bug fixes:- Improved mouse wheel behavior for precision devices (e.g., Surface Precision Mouse).
- Changed the maximum split screen layout to 5x5.
- Changed: the location overlay now shows the position of the center of frame for images with non-orthogonal orientation.
- Added support for overlays with non-zero origin.
- Added support for per-frame overlays in multi-frame DICOM files.
- Added option to launch structured reporting documents in the external web browser (Ctrl + Enter).
- Added support for SUV calculations in studies acquired with Siemens Biograph PET-CT.
- Added support for TIC generation in studies acquired with Toshiba Vantage MRI.
- Added the "Save RAW value" option in the DICOM tags window.
- Fixed several bugs causing crashes and memory leaks.
- Other performance improvements.
Improvements and bug fixes:- Improved support for breast tomosynthesis images (DBT).
- Improved support for files that are not fully compliant with the DICOM standard.
- Improved support for ultrasound images retrieved from Synapse PACS.
- Fixed occasional crashing issues.
New features:- 3D cursor tool in the 2D Viewer window.
Improvements and bug fixes:- Added support for changing series with mouse wheel (horizontal scroll).
- Added configurable key modifiers and mouse button combinations for all tools.
- Added modality column to the "Open multiple series" window
- Added support for not fully compliant DICOM JPEG files.
- Fixed image fusion for non-standard (non-orthogonal) orientations.
- Fixed occasional crash when exporting WMV videos.
- Fixed crash when opening DICOM files with certain LUT Descriptor.
- Fixed: some endemic DICOM files with certain private tags could not be opened.
Improvements and bug fixes:- Fixed display of certain RGB lossy JPEG DICOM images.
- Configurable units and precision for length measurements (options.xml).
- Added option to display a mark in the middle of a segment (options.xml).
- Added option to display a mark in the center of an ellipse (options.xml).
Improvements and bug fixes:- Added quick search in the "Open series" window (F4).
- Added support for DICOM Deflated Little Endian Transfer Syntax (Explicit VR) (1.2.840.10008.1.2.1.99).
- Improved series sorting in the "Open series" window (F4).
- Improved default WW/WL calculation for multi-frame images.
- DICOM dictionary updated to 2017d.
- Fixed: RGB images with incorrect WW/WL were not displayed properly.
- Fixed: rare type of JPEG compressed images could not be opened.
- Optimized memory management.
Improvements and bug fixes:- Images from non-volumetric series (CR, DX, MG, US, XA, etc.) can be split into separate panels
- Improved support for certain palette color DICOM images (US Philips)
- Improved support for series of images without StudyUID or SOPInstanceUID
- Improved support for certain files not fully compliant with the DICOM standard
- Default DICOM character set can be overridden in the options.xml file
- Language xml files are now checked for incorrect format specifiers
- Fixed several bugs causing crashes and memory leaks
New features:- Copy all visible panels to clipboard as one image.
Improvements and bug fixes:- Added support for certain type of ultrasound images (Aloka).
- Added custom split screen setup via command line parameters (e.g. -sp 3 2) or the options.xml file.
- Fixed: JPEG compressed images could give linear artifacts in MPR views.
- Fixed: MPR and VR features were not available for certain type of SPECT images.
- Other minor improvements.
New features:- Manual series synchronization (slice position, zoom&pan, window settings).
- Separate toolbar button for changing synchronization mode.
- New functionalities in the DICOM tags window: search text, copy all items, copy selected item, show DICOM file in explorer.
- 2D MPR now works with CT series acquired with tilted gantry.
Improvements and bug fixes:- Improved auto synchronization - non-parallel series with a dihedral angle up to 5 degrees are now synchronized automatically.
- Fixed: the encapsulated MPEG videos were not opened properly without VLC installed.
- Quicker series thumbnail generation when multiple series are located in one folder and the DICOMDIR file is present.
- Other performance improvements.
Improvements and bug fixes:- Sorting mode of studies in the series preview bar can be changed to "newest first" via options.xml file.
- Fixed: cine loops exported to WMV files had sometimes incorrect frame rate.
New features:- Support for the encapsulated PDF documents (opened in an external viewer).
- Support for the MPEG-2 / MPEG-4 DICOM files (opened in an external media player).
- New measurement tool: Deviation.
Improvements and bug fixes:- Negative mode can be enabled by default for NM (Nuclear Medicine) images via the options.xml file.
- Last export destination folder is remembered after closing RadiAnt.
- Improved stability and efficiency.
- Fixed: The logo JPEG image caused crash when CMYK color space was used.
- Fixed: exported files are not overwritten during subsequent exports to the same folder.
- Fixed: a bad date in a DICOM file could cause RadiAnt crash.
- Fixed: a specific type of JPEG LS compressed images was not displayed.
Improvements and bug fixes:- Fixed issue with measurements showing 0mm in images obtained from Philips Achieva MRI scanner.
Improvements and bug fixes:- Improved support for a specific type of DICOM images (HITACHI MRI).
- Improved performance and stability.
- Fixed a rare crash while scanning for DICOM files.
Improvements and bug fixes:- Improved support for legacy DICOM overlays.
- Fixed rare crashes on Windows 7 64-bit without SP1.
- Fixed rare crashes on Windows XP 32-bit with older CPUs.
Improvements and bug fixes:- Improved support for specific DICOM files (Philips Intera MRI, GE Optima MRI).
New features:- Support for the SR (Structured Reporting) Documents.
Press Enter to display a SR DICOM file in the HTML browser.
Improvements and bug fixes:- Improved stability, other small fixes.
New features:- "Split series" feature detects multiple volumes contained in one series (e.g. arterial/venous post-contrast, DWI, cardiac CT multi-phase) and opens them in separate panels.
- Dedicated window presets for PET modality (0.5, 1, 2.5, 5, 10, 25, 50 and 100 percent of the entire dynamic range of the displayed series).
Improvements and bug fixes:- In series consisting of multiple volumes (sequences), MPR is applied to the volume whose frame is currently displayed.
- Improved display of PET images with small pixel values (especially those without attenuation correction).
- Improved calculation of the default contrast/brightness values for PET images.
- Default color look-up table for PET changed to Hot Iron.
- Fixed MPR and Fusion functionality for special type of PET images (Siemens scanner).
- Improved export of all opened series.
- Enhanced support for compressed images.
- Fixed display of rare ultrasound images.
- Improved stability, lowered memory usage, other small fixes.
Improvements and bug fixes:- Improved support for SPECT-CT studies (synchronization, MPR, fusion).
- Improved automatic synchronization of series with small difference in patient orientation (e.g. MR).
- Added support for a rare type of dicom files with little endian implicit transfer syntax.
- Fixed ocassional crash of the viewer.
- Other minor improvements.
Improvements and bug fixes:- Fixed display of certain types of images with PALETTE COLOR photometric interpretation.
- Fixed display of rare type of images with big endian transfer syntax.
- Other minor improvements.
New features:- Support for length measurement using estimated radiographic magnification factor (e.g. in mammography images).
Improvements and bug fixes:- Enhanced PET SUV measurements (e.g. Philips scanners support).
- Fixed display of certain types of images with VOI LUT.
- Other minor improvements.
New features:- Customizable annotations.
- Support for manual length calibration.
- US calibrated regions support (length or other parameters such as time, velocity, depending on the region).
Improvements and bug fixes:- Changed structure of folders and filenames (for compliance with ISO 9660 Class 1 8+3 filename system)
- CD/DVD scanning can be narrowed down to specified folder(s) (-d command-line parameter)
- The "run.bat" file starts launcher.exe tool, which runs either 32-bit or 64-bit version of RadiAnt DICOM Viewer (previously always 32-bit version was opened)
- Imager pixel spacing is used for measurements when available (which is often the case for XA images).
- Faster opening of large image series from cd/dvd media (in systems low on memory)
- Fixed handling of certain JPEG2000 DICOM files.
- Fixed visual artifacts in ROI elements in exported images.
- Improvements in DICOM tags preview window (fixed incidental crashes, enhanced tag descriptions, corrected display of tags with multiple numerical values).
- Other minor improvements.
New features:- Multi-touch support for Windows 8 touch-enabled devices:
- Use one finger to browse images of the series (or perform other function selected from the toolbar).
- Use two fingers to pan and zoom (pinch) images.
- Use three fingers to change window settings (brightness/contrast).
- Time-Intensity Curve generation (CTRL + SHIFT + E).
- Export files in DICOM format.
- Zoom & pan synchronization.
- Window settings (WW/WL) synchronization.
- New controls for Cine mode, overlayed at the bottom of the screen when mouse hovers over image.
- Cine auto start for US and XA series.
- Edit ROIs:
- Copy selected ROI (CTRL + C)
- Copy all ROIs in displayed image (CTRL + SHIFT + C)
- Paste ROI(s) in the same or in different image (CTRL + V)
- Duplicate ROI in corresponding series (CTRL + SHIFT + D)
- Duplicate ROI in all images of the series (SHIFT + ALT + D)
- Delete ROIs in all visible images (SHIFT + DEL)
- Open quickly multiple series (F4).
- Change color scale in fusion images (click color bar).
- Change fused image opacity (left mouse button down and drag over color bar).
- Maximize/restore panel (button/double click on image/CTRL + M), you can switch between opened series in maximized panel using TAB.
- Anonimize all visible patient data (SHIFT + F12).
- Tools can be assigned to the middle mouse button (with WL/WW adjustment default).
Improvements and bug fixes:- Significant reduction of CD/DVD loading times (up to 3x faster).
- Improved multiframe DICOM file reading from CD/DVD.
- Detection of CD/DVD/Flash removal.
- Toggle series preview bar visibility (CTRL+SHIFT+F4).
- Toggle toolbar and status bar visibility (CTRL+SHIFT+F3).
- Toggle ROI visibility (ALT+F12).
- Change ROI label font size (CTRL+SHIFT+PLUS/MINUS).
- Hold SHIFT during ellipse drawing to make it a circle, hold it while drawing a segment to make it horizontal or vertical.
- Hold CTRL during ellipse drawing to show actual DICOM pixels area (only when image is magnified).
- Ellipse ROI label shows actual DICOM pixels number used for calculations.
- Close all panels (SHIFT + F4).
- Click panel close button with CTRL pressed to clear the panel instead of closing it.
- Options.xml file - change default options.
- Zoom-to-region mode for zooming tool (available in options.xml).
- Off-center zooming (retains desired image region visibility during zooming - available in options.xml).
- Scroll wrapping can be disabled in options.xml file.
- Added WW/WL presets for modalities other than CT.
- Status bar shows remaining files during folder scan.
- Displayed info about lossy compression of DICOM images (left top corner, below series number).
- CTRL + C copies value to clipboard in DICOM tags window.
- Improved support for images with VOI LUT defined.
- Fixed a rare crash caused by images with "RAW" modality.
- Fixed display of certain US images (e.g. Philips US systems, GE Vivid 7).
- Fixed default cine rate setting (FPS).
- Compatibility with Windows Server 2008 system was improved by removing the dependency on wmvcore.dll library.
- Other minor features and bug fixes.
Improvements and bug fixes:- Better support for the new enhanced multi-frame DICOM CT and MR files - measurements, default window parameters, auto synchronization, cross reference lines, MPR and image fusion.
- SD (standard deviation) calculation in ellipse ROI.
- Fixed issue with ellipse ROI calculations in fusion MPR (coronal and sagittal) images.
- Faster DICOM load and export times.
- Better memory management.
New features:- Multiplanar reconstructions.
- PET-CT fusion (other types of images can be also fused, e.g. DWI and conventional MRI sequences).
- Screen splitting with a predefined column/row number (drag and drop series thumbnail images into viewports).
- DICOM tags inspection window.
- Angle measurement.
- Cobb angle measurement.
Improvements and bug fixes:- The autorun package for CD/DVD contains both 32 and 64 bit versions.
- Crash reporting tool.
- More keyboard shortcuts (series navigation - Home/End, tool selection - C/B/M/W/Z).
- Middle mouse button adjusts window level/width.
- Support for PALETTE COLOR DICOM images.
- Improved support for JPEG DICOM images.
- Auto synchronization on/off switch.
- Display cross-reference lines on/off switch.
- ROIs drawn with an outline for better visibility on brighter backgrounds.
- Movable ROI text labels.
- Improved look of certain dialog windows when using non-standard DPI settings.
- Ellipse tool shows minimum and maximum values in covered area.
- More zoom presets added - 200, 400 and 800%.
- Other minor features and many bug fixes.
New features:- Export to movie files (WMV).
- Export all opened series at once.
- Support for DICOM overlays.
- Show/hide annotations using button or shortcut (F12).
Improvements and bug fixes:- Faster image operations (zooming, panning) and lowered memory usage, especially with larger (CR, DX, MG) images.
- Date and time formatted using local system settings.
- Zooming using Ctrl + Mouse Wheel.
- Menu items for adding images to the thumblist without clearing it.
- Improved CINE display efficiency (interface was freezing with multiple cine runs at the same time).
- Improved patient sorting in the thumblist.
- Improved drawing of certain types of images (e.g. dose reports).
- Improved color images display.