Basic Functionality |
Autorun package for distribution on optical discs and flash memory
as a DICOM CD/DVD/USB viewer running without installation on Windows systems
(with the option to read password-protected, AES-256 encrypted DICOM data)1 |
Windows 7/8/8.1/10/11 supported |
No additional dependencies (.NET, Java, etc.) |
Lightweight, compact application2 |
Excellent performance with 32- and 64-bit versions that are both optimized for multi-core processors |
Asynchronous reading (you can browse images as they are being opened) |
Advanced memory management system that facilitates the concurrent opening of studies that contain thousands of images |
Supported DICOM Formats |
Files from different imaging modalities: CR, DX, MG, CT, MR, PT, US, XA, NM, SC, SR |
Monochromatic images (e.g., CR, CT, MR) |
Color images (e.g., US, 3D reconstructions) |
Static images (e.g., CR, MG, CT) |
Dynamic sequences (e.g., XA, US) |
Uncompressed images (little endian/big endian, implicit/explicit VR) |
Compressed images (RLE, JPEG Lossy, JPEG Lossless, JPEG 2000, JPEG-LS) |
Structured reports |
Encapsulated PDF documents |
MPEG4/MPEG2 DICOM videos |
Access DICOM Studies |
Open DICOM studies from CD/DVD/Blu-ray discs3 |
Open DICOM studies from USB drives3 |
Export Images |
Export DICOM files to JPEG/BMP images |
Export DICOM files to MP4/WMV movies |
Export DICOM files in original format4 |
Copy displayed image to Windows Clipboard |
Basic Tools |
Perform fluid zooming |
Perform fluid panning |
Adjust brightness and contrast (window level/window width) |
Negative mode |
Apply window presets for computed tomography (lung, bone, etc.) |
Apply precise window values (with SUVbw support for PET series) |
Rotate (90 CW, 90 CCW, 180) |
Flip (horizontal, vertical) |
Apply image filters (sharpen, smooth, edge, emboss) |
Display dynamic series/sequences (CINE) with option to adjust frames per second |
Display DICOM overlays (annotations or graphic overlays included in the file) |
Display DICOM file structure with searchable DICOM tags, their descriptions and values |
Measurements/ROI |
Measurement of segment length |
Manual calibration of length measurements |
Support for calibrated regions in ultrasound images |
Measurement of mean, minimum and maximum parameter values (e.g. density in Hounsfield Units in computed tomography, SUVbw in PET) within circle/ellipse and its area |
Measurement of area and perimeter of a closed polygon |
Measurement of open polygon length |
Measurement of angle value |
Measurement of Cobb angle value |
Measurement of deviation distance |
Arrow tool for annotations |
Pencil tool for freehand drawing |
Compare Series |
Compare multiple series in the same or different windows |
Automatic synchronization between series with images acquired in the same plane (e.g., computed tomography series before and after contrast media administration)5 |
Manual synchronization between series from different studies that have a similar patient orientation |
Cross-reference lines in series with different image planes (e.g., magnetic resonance study)5 |
3D cursor tool |
Split multi-sequence series into separate panels |
Advanced Tools |
2D MPR (orthogonal multiplanar reconstructions) |
Fusion of series with different modalities (e.g., PET-CT) or with different protocols (e.g., MR T1/T2 – DWI) |
Time-intensity curves (TIC, e.g., for breast MRI) |
Interface |
A simple and intuitive interface with full-screen and distraction-free modes |
Multi-touch support for Windows 8/8.1/10/11 touch-enabled devices |
Multilingual interface—more than 30 translations available6 |
Customizable keyboard shortcuts |
1 You should use your own software and hardware (e.g., a disc publisher) to burn the contents of the autorun package (with the license key file) along with the DICOM study files to the CD/DVD media (or record to USB Flash). RadiAnt DICOM Viewer cannot burn CD/DVDs by itself.
2 RadiAnt DICOM Viewer CD/DVD adds 11MB overhead to the CD/DVD (when both 32- and 64-bit versions are included).
3 RadiAnt DICOM Viewer CD/DVD can only run from the CD/DVD discs or USB Flash removable drives and display images stored on the media on which it runs. It cannot be started from your local hard drive. Furthermore, DICOM studies cannot be opened from locations other than removable media the viewer was recorded on.
4 It is not possible to export secondary images obtained using Multiplanar Reconstructions (MPR), 3D Volume Rendering, Fusion, or Time-intensity Curve (TIC) tools to DICOM files.
5 The series have to belong to the same study.
6 RadiAnt DICOM Viewer and RadiAnt DICOM Viewer CD/DVD are distributed with English and Polish language support. Other translations (Arabic, Brazilian Portuguese, Bulgarian, Chinese, Chinese [Taiwan], Croatian, Czech, Danish, Dutch/Flemish, French, German, Greek, Hungarian, Indonesian, Italian, Japanese, Korean, Mongolian, Norwegian, Persian, Portuguese, Romanian, Russian, Serbian, Slovak, Spanish, Swedish, Turkish, Ukrainian) have been created by the community and are available for download from
https://www.radiantviewer.com/translations/. Not all translations have been updated for the newest version of the viewer.